Biochemistry Kits : Liquid biochemistry kits of routine and special parameters like urea, Creatinine, Sugar Cholesterol, Triglycerides, Na+, K+ etc.

The reagents are usable in automated, semi automated chemistry analyzers and colorimeters.


   Albumin Analysis Kit - Methodology

Ready to use single liquid reagent (BCG method).

The linearity limit up to 6g/dl.

Reaction – End point chemistry.

Quick incubation – 5 minutes at 37ºC.

Colour is stable for about 1 hour.

Wide range of pack sizes to suit.


   Alkaline Phosphatase - Analysis Kit Methodology

Ready to use  liquid reagent after reconstitution with substrate in tablet form (liquistable IFCC method).

The linearity limit up to 600 IU/L.

Reaction – End point chemistry.

Colour is stable for about 1 hour.

Very low detection limit : 5 IU/L.

Wide range of pack sizes to suit.

Bulk packing size also available.


   Bilirubin Analysis Kit - Methodology

Ready to use two reagent system (liquistable).

Highly stable Reference Standard included.

The linearity limit up to 50mg/dl.

Reaction – End point chemistry.

Quick incubation – 10 minutes at 37ºC.

Colour is stable for about 1 hour.

Wide range of pack sizes to suit.


   Creatinine Analysis Kit - Methodology

Ready to use two reagent system (liquistable Modified Jaffe method).

The linearity limit up to 12mg/dl.

Reaction – two point chemistry.

Very low detection limit: Can estimate accurately from 0.5mg/dl.

Wide range of pack sizes to suit.

Bulk packing size also available.


   Calcium Analysis Kit - Methodology

Ready to use double liquid reagent orthocresolphthalein complexone method (OCPC Method).

The linearity limit up to 15mg/dl.

Reaction – End point chemistry.

Quick incubation – 10 minutes at 37ºC.

Colour is stable for about 1 hour.

Very low detection limit: 1mg/dl.

Wide range of pack sizes to suit.


   Glucose Analysis Kit - Methodology

Ready to use single liquid reagent (GOD-PAP Enzymatic method).

The linearity limit up to 500mg/dl.

Reaction – End point chemistry.

Short incubation – 10 minutes at 37ºC.

Colour is stable for about 1 hour.

Wide range of pack sizes to suit.

   SGPT Analysis Kit - Methodology

Ready to use two reagent system (IFCC method).

Reaction time 3 minutes.

low detection limit : 5 IU/L.

high detection limit : 265 IU/L.

Wide range of pack sizes to suit.

Bulk packing size also available.

   SGOT Analysis Kit - Methodology

Ready to use two reagent system (IFCC method).

Reaction time 3 minutes.

Low detection limit : 5 IU/L.

High detection limit : 260 IU/L.

Wide range of pack sizes to suit.

Bulk packing size also available.

   Triglycerides Analysis Kit - Methodology

Ready to use single liquid reagent (GPO-PAP method).

The linearity limit up to 800mg/dl.

Reaction – End point chemistry.

Quick incubation – 10 minutes at 37ºC.

Colour is stable for about 1 hour.

Wide range of pack sizes to suit.

   Total Protein Analysis Kit - Methodology

Ready to use single liquid reagent (liquistable).

The linearity limit up to 12g/dL.

Reaction – End point chemistry.

Colour is stable for about 1 hour.

Very low detection limit : 0.2g/dL.

Wide range of pack sizes to suit.

   Urea Analysis Kit - Methodology

Ready to use two reagent system ( Berthelot method).

The linearity limit up to 200mg/dl.

Reaction – End point chemistry.

Very low detection limit: 5mg/dl.

Short incubation – 10 minutes at 37ºC.

Colour is stable for about 1 hour.

Wide range of pack sizes to suit.

Bulk packing size also available.